Functional elements

A Cover screws Pozidrive 1: 0.74 ft lbf
B Cover
C LED
Light on:
On
Light flashing: Error
D Test button
E Ribbon cable
F Inlet opening 3/4" ISO 228/1
G Key area 3/4"
H PG 9 screw connection for potential-free
contact 3,4 (option)
I
Potential-free contact 3,4
J Power supply, contact 1,2
K Earthing connection, PE
L PG 9 screw connection for power supply
M Collecting area seal
N Drain plug
1)
O Condensate collecting area
P Membrane
Q Fastening holes for attachment to a
console (self-tapping screws,
ø Nr. 12; Lmax = 3/4")
R Screws (2x), fine thread
TORX
®
25; 5.5 ft lbf
S Screws (4x), coarse thread
TORX
®
20; 4.8 ft lbf
T Condensate drain and drain adapter
U Replacement parts set
(without membrane adapter V)
V Membrane adapter
1)
to
2)
according to configuration
8

For your safety

You as operator / user of the unit should
make yourself familiar with the function,
installation and start-up of the unit through
these operating instructions.
It is essential that you follow these safety
notes and this information in order to ensure
trouble-free operation of the unit.
All the safety information in always intended
to ensure your personal safety!
The pressure and temperature of the
medium must match the details given on
the type plate of the unit!
Installation work may only be carried out by
trained and experienced specialists.
Disconnect the power supply when carrying
out electrical work!
Wear protective glasses when working with
media under pressure.
Risk of explosion! It is not permitted to use
this unit in areas at risk from explosion or
with explosive or inflammable media!
It is forbidden to carry out any kind of work
on the pressure vessels and piping, this
covering welding, constructional changes,
installation work, etc. Breaking this rule
means extreme danger for you and your
colleagues.
Depressurize the system before carrying
out any work on the piping.
2)
Clean the piping before carrying out the
installation work.
Each tank must have its own condensate
drain.
Make a visual check before the initial
startup. There must be no external damage
visible.
Use the unit for the appropriate purpose!