Installation Instructions – ClearCurve Wall
INSTALLATION
This lighting fixture has been shipped complete. Please
follow the installation instructions specific to the catalog
part that you ordered.
Care must be taken not to set lighting fixture down
N
ote:
on optical lenses or lift the fixture in the lens area.
WALL MOUNT (AC POWER THROUGH THE BACK OF
THE FIXTURE)
Tools Required:
#2 Phillips head screwdriver, 1/8" Hex
allen wrench, torque wrench, tool for screw mounting
hardware (by other).
1.
Remove the wedge plate by loosening the two set
screws on the fixture (Figure 1).
5.25"
Set screws
Figure 1.
2.
Attach the wedge plate to the wall over the junction
box (Figure 2). The wedge plate must be mounted with
hardware able to support a fixture weight of up to
50 lbs.
Note: The fixture is sealed and does not require any
additional water proofing silicone caulk.
Surface Mount / Recessed Junction Box
Surface Junction Box
Figure 2.
3.
Hang the fixture from the wedge plate using the
ball ended cable located on the back of the fixture
(Figure 3).
2
Cooper Lighting Solutions
Ø.28"
or
IB516118EN
Installation Instructions
Place ball end cable in slot
to hang fixture
Figure 3.
4.
Make wiring connections per wiring diagram
(Figure 4A, or 4B or 4C).
N
ote:
Dimming wires will not exit fixture when fixture is
ordered with motion control device. If external
dimming control is not used then separately cap off
gray and purple wires.
(+) Line
(-) Common
Ground
Dimming Control
0-10V
Figure 4A. Standard Configuration
Plug When Installed (Red)
Unswitched Power
Dimming
Figure 4B. Emergency Battery Pack
Black
White
Green
Fixture
Gray
Purple
Black
Black/White
Fixture
White
Green
Gray
Purple