Instructions for use – LFM and LFM Medical
Illuminated magnifier – 22 W
General information
Magnifying lamp with circular T8 light tube.
Installation:
This product contains a spring loaded arm. In order to avoid damage or possible
injury, first mount table bracket or floor stand. Insert product and remove protective
plastic sleeve or rubber band, and carefully unfold the product.
For dismounting/mounting of sun cover and addition lens please see page 3.
Always use enclosed table bracket, article number 8990-010 or optional floor stand
8990-028.
Luxo cannot guarantee the lifetime and functionality if third part accessories are
used.
Precautions:
– Avoid spilling liquid on the lamp head
- NB! Never open the lamp head while the current is connected.
Replacing the light source
Start by switching off the power at the mains and removing the plug.
1. Remove the light source cover (see fig 1)
2. Use both hands to remove the light source (see fig. 2)
3. Remove the starter by unscrewing it counter clockwise (see fig. 2)
Fit the new light source by reversing the above procedure.
Cleaning
Open the lamp head as described above. Blow and dry off any dust and dirt.
Using of different cleaning agents for cleaning this product:
Avoid use of alcohol,acids or any kind of organic solvents (Isopropanol etc.)
Only use the weak mix of ordinary soap and water without any perfumes.
Troubleshooting
1. The luminaire does not work.
•
Replace the circular 22W T8 light tube
2
For qualified electrical fitters and other similarly qualified personnel
•
Check the mains connection
•
Replace the fuses (NB! Only on MEDICAL version)
⇒
Remove the lamp from mains supply.
⇒
Loosen the screw and remove ballast box cover
⇒
Exchange fuses
⇒
Replace ballast box cover, and tighten the screw
Should there arise other problems please contact your local LUXO representative.
ART.: 05-900-585-00
BRU-303-0029 Rev.nr.: E