Keypad Operation {B} inside front cover
1. Power Switch – Turns the detector on and off. The RE Digital will go
through a brief (3 seconds) start-up procedure as the unit goes
through a self-calibration procedure.
Do not power up the detector while in the laser beam or in front
of a strobe light. If detected, the unit will revert to the previous
calibration.
2. Units of Measure Switch – Press once to display the current unit of
measure. Press again to change the unit of measure. Selections are
millimeters (MM), centimeters (CM), inches (IN), fractions of an inch
(FRAC) or feet (FT).
3. Audio Switch – Selects the audio level. Press to select high, medium,
low or off.
4. Accuracy Switch – Press once to display the current accuracy
setting. Press again to change the accuracy. There are five accuracy
settings: ultra fine, super fine, fine, medium and coarse.
5. LED Brightness – Press the Units and Audio switches together to
change the LED's from ON-Bright, On-Normal or Off.
6. Menu – Press the Accuracy and Audio switches together to enter the
menu functions. Details follow in a later section.
6a. In menu mode, the up arrow scrolls the menu up.
6b. In menu mode, the down arrow scrolls the menu down.
6c. In menu mode, the enter arrow enters or selects the option.
7. Capture – Allows a reading to be recorded.
Liquid Crystal Display {C} inside back cover
1. Grade Indication Arrows – Ten channels are displayed for above
and below grade.
• Arrow bars can be selected to represent the selected accuracy
bandwidth or can be proportional to the vertical reception range.
(see ARRW in menu section to select)
• Out of Beam Display – If the detector is moved out of the detector
range, the arrow display will indicate the direction to move to
return to the laser beam. (see O.O.B. in menu to enable/disable)