Rational EH Instrucciones De Instalación página 11

Combimaster plus cmp 61g; combimaster plus cmp 62g; combimaster plus cmp 101g; combimaster plus cmp 102g; combimaster plus cmp 201g; combimaster plus cmp 202g; selfcooking center whitefficiency scc we 61g; selfcooking center whitefficiency scc we 62g; sel
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
Installation instruction
Equipotential bonding
Also on the rear side of the UV/EH there is a
stud for the equipotential bonding. Integrate
the UV/EH with a suitable cable into the
equipotential bonding system.
Observe on Combi-Duo:
- Connect the vent pipe of the Combi-Duo to the con-
nection piece of the UV/EH using hose (item 9) and
hose clamp (item 10) of the UV/EH kit.
- Installation of the bus cable:
There are two bus cables connected to the control
pcb. Use the longer cable for the bottom unit and
the shorter for top unit. Connect the cable as
described under point 4.
Observe on gas units
- Connect the bus cable to a free connector of the
ignition box (see point 4)
- UV/EH gas is shipped with 3 extension
pipes for exhaust system. For unit size 6x1/1 GN
one pipe with outer diameter 42 mm and one pipe
with outer diameter 54 mm is required. Unit size
10x1/1 GN requires two pipes with outer diameter
54 mm. Attach the required pipes to the corre-
sponding exhaust pipe of the unit..
In case an additional draft diverter is ordered with
UV/EH these pipes are not required. The draft
diverter is shipped with extra longer pipes (see
installation instruction of draft diverter)
- The use of this EH or Ultravent does not
replace the flue gas evacuation via extraction hood,
ventilated ceiling or chimney.
- If the waste gas of the combi steamer is
removed by means of a chimney, then a draft
diverter must be fitted to the exhaust opening of the
UltraVent
.
®
- The draft diverter is not included in the scope of
supply of the unit, but can be ordered with the fol-
lowing part number:
6x1/1 GN # 70.00.759
10x1/1 GN # 70.00.793
7. Technical intervention
Before any intervention or maintenance work,
disconnect the appliance from the power supply.
7.1 Fan motor.
Fan motor is accessible after removing the
fat filter.
7.2 Changing halogen bulb.
After loosen the holding frame, the halogen bulb
can be changed.
pic. 9
8. Wiring diagram
see pictures C/D/E/F
9. Service parts
Description
Control pcb
Bus cable
Bus cable (4,3m Duo)
Fuse 5 x 20 2,5A
Halogen bulb
pic. 19
Inner gasket for interior light
Glass pane for interior light
Gasket frame for interior light
Fat filter left
Fat filter right with lock
Adapter plate left hinged door
(Pos. 1) 61/101
Adapter plate right hinged door
(Pos. 1) 61/101
Adapter plate right hinged door
(Pos. 1) 62/102
Gasket adapter (Pos. 2) 61/101
Gasket adapter (Pos. 2) 62
Gasket adapter (Pos. 2) 102
Gasket adapter (Pos. 2) 201
Stud (Pos. 7)
Drain pipe (Pos. 6)
Silicone hose
Contactor k1/K2
Capacitor 3,5 uF
Capacitor 10 uF
Capacitor 14 uF
Capacitor 40 uF
Voltage related parts
Extractor fan 200-240V (M1)
Extractor fan 100-127V (M1)
- 11 -
42.00.050
40.04.148
40.04.146
3019.0117
3024.0201
40.00.094
40.00.095
40.00.092
60.72.440
60.72.441
60.72.891
60.72.936
60.72.937
60.72.431
60.72.433
60.72.435
60.72.445
60.72.892
60.70.735
2110.1008
40.03.687
40.04.151
40.04.152
40.04.229
40.04.230
for input voltage:
60.72.439
60.72.701
UV/EH V06 08/2015
pic. 17
pic. 18
Art. No.

Publicidad

Tabla de contenido
loading

Productos relacionados para Rational EH

Este manual también es adecuado para:

Ultravent uvUltravent plus uv plus

Tabla de contenido