Troubleshooting (continued)
REMOVING VALVE CAP ASSEMBLY
Turn off water supply and flush out tank. Push float
up with right hand (see picture). Grip and hold shaft
under float with right hand. With left hand, twist cap
and lever counter clockwise 1/8 of a turn to unlock
the top cap. Pressing down on top may be helpful
with older valves. Let cap assembly hand out float
cup.
FLUSHING OUT DEBRIS
Hold cup upside down over uncapped valve to
prevent splashing. Turn water supply on and off a
few times. Turn water supply off when putting cap
back on valve.
IF REPLACING SEAL
Use only a genuine Fluidmaster 242 seal.
REPLACING VALVE CAP
1.
Place cap assembly on top of grey valve body
by aligning cap arm and adjustment rod next to
refill tube.
2.
Press down on top cap while rotating top
arm clockwise to locked position.
Replacement Parts List
Part Name
Fill Valve
Flush Valve
Flush Valve Seal
Model Number
C7702-7
C7702-6
C7702-SS
242
242
SEAL
SEAL
1
2
A
B
9
Please contact 1-800-831-8383 for further assistance.