GB
INSTALLATION GUIDE
Savtec is the suction shut-off valve for Sunfab's SL pumps in the 200
series. Savtec is intended for installations where the power take off is not
disengaged during transport.
INSTALLATION
Connect the valve with the flange halves
➁
Connect the short oil line
the under side of the pump.
Use seal washers on each side of the nipple.
Complete the routing with a 13 mm (½") hose
of the pump directly to the oil tank. The connection to the oil tank should
be below the oil level.
Otherwise see SL pump installation guide 7006.
AIR CONTROL
➄
The angled nipple
is the compressed air connection for opening the
➅
valve. The straight nipple
is routed to a protected location.
Nipple diameter: 6 mm.
Sunfab reserves the right to make changes in design and dimensions without notice. Printing and typesetting errors reserved.
© Copyright 2017 Sunfab Hydraulics AB. All Rights Reserved.
Sunfab Hydraulics AB, Box 1094, SE-824 12 Hudiksvall, Sweden. Tel: +46 650-367 00, Fax: +46 650-367 27, E-mail: sunfab@sunfab.se Web: www.sunfab.com
➀
. Tighten the screws alternately.
➂
using banjo nipples
between Savtec and
➃
between the upper side
is the ventilation connection for a hose which
80 Nm
GB/US | SE | DE | ES | FR | IT | NO | FI | DK | PT | NL | PL | GR
2
38 mm (1½")
Q
= 65 l ⁄min
max
50 mm (2")
Q
= 120 l ⁄min
max
64 mm (2½")
Q
= 185 l ⁄min
max
75 mm (3")
Q
= 265 l ⁄min
50
(2")
mm
max
64
(2½")
mm
3
20/20, 28/28, 35/35, 46/46, 53/53
40/20, 56/28, 64/32
SAVTEC
24 Nm
150 Nm
60 Nm
60 Nm
7007INT1711 REV 1.3 1/4