BYPASS
HUMIDIFIER
VENTILATOR
OR
DEHUMIDIFIER
MOUNT RETURN
SENSOR HERE
MOUNT DOWNSTREAM
OF BYPASS HUMIDIFIER,
DEHUMIDIFIER OR
VENTILATOR
MOUNT
DISCHARGE
SENSOR IN
EITHER LOCATION
ABOVE CENTER
OF A-COIL
MOUNT UPSTREAM
OR DOWNSTREAM
OF BYPASS
HUMIDIFIER
HEAT
EXCHANGER
BLOWER
Fig. 6.
50062329-001 DISCHARGE/RETURN AIR SENSOR
INSTALLATION
Use the following steps to mount the Discharge/Return Air
Sensors:
1. Attach plastic cover to the sensor probe.
2. Drill 1/4-inch hole for the sensor probe and mount it
to the ductwork with enclosed screws (see Fig. 7).
3. Connect wires to S1 or S2 terminals at the EIM.
4. Configure the S1 or S2 terminals in the Installer
Setup at the thermostat.
Fig. 7. Mounting Discharge/Return Air Sensor.
M33079
3
M32995
69-2678EFS—01