Warnings and Cautions
WARNING: This high-capacity flow-thru humidifier must be installed by
!
a qualified heating and air conditioning contractor. Failure to comply could
result in serious injury from electrical shock, or damage to the humidifier or
heating appliance Failure to comply could also vid all warranties.
ADDITIONAL WARNINGS:
1. Disconnect electrical power to the
furnace before starting installation to avoid
serious injury or electrocution.
2. Use care when cutting plenum
openings and handling ductwork. Sharp
edges may cause serious injury.
3. Do not cut or drill any air conditioning
or electrical accessories during
humidi fier installation. (See "Placement"
diagrams, page 1.) Electrocution is
possible if you come in contact with a
live electrical wire; blindness can occur if
refrigerant contacts your eyes.
CAUTIONS:
1. Do not install the unit where freezing
temperatures could occur, or where
temperatures could exceed 180°F
(82.22°C).
2. Do not install the unit on a furnace jacket.
ENGLISH
Contractor Assistance:
Phone: 888-SKUTTLE (758-8853)
Email: techservice@skuttle.com
Web: www.skuttle.com
3. Do not install the unit on a plenum face
4. Do not set humidity higher than recom-
5. Do not set humidity up to recommended
6. Do not install the unit on any plenum
7. Do not install the unit where water
8. Be sure that the installation, wiring and
where the blanked-off ends of the cooling
coil restrict air movement through the
humidifier.
mended. Condensation damage may
result.
levels if there is condensation on the inside
windows of any living space. Condensation
damage may result.
where static pressure exceeds 0.4 in. (1.02
cm) W.C.
pressure exceeds 125 psi (861.85 kPa).
Leakage may result. Follow relevant codes
regarding pressure reduction.
plumbing on the humidifier comply with
local codes, ordinances and regulations.