Step-by-Step Installation Instructions
Models 2001 cutout size is 10-5/8 in. (26.99 cm) wide
by 16-5/8 in. (42.23 cm) wide.
1. Locate the 2000
or 2001 mounting
template in the
humidifier carton.
Tape the template
lengthwise onto the
furnace plenum,
making sure it is
level.
2. Trace around the
template.* Remove the
template. Accurately
cut the plenum
opening.
*Models 2000 cutout size is
9 in. (22.86 cm) wide by 10
in. (25.40 cm) long.
3. Disengage the
humidifier cover from
the mounting frame
by rotating the thumb
screw at the bottom
counterclockwise ().
4. Tilt and lift the cover
off the frame.
5. Pull out the drip tray
and evaporator pad
assembly by grasping
the top lip and tipping
out.
NOTE: Photos shown here and on the
following pages are of the Skuttle 2000
Flow-Thru Humidifier. The 2001 unit is
somewhat larger, however, instal lation
procedures for both models are identical
unless otherwise noted.
2
6. To convert the
humidifier from right-
to left-side discharge,
apply pressure to the
inside of the side panel
using both hands. Lift.
Exchange the two side
pieces. Reinstall using
moderate pressure.
7. Place the mounting
frame into the plenum
opening so that the
frame hooks over the
bottom of the opening.
Screw the frame to the
plenum.
8. Stand the
evaporator pad
upright with the
index mark on top.
Make sure the wick
is seated securely in
the drip tray.
9. Place the drip
tray on top of the
pad. Reinstall the
evaporator pad and
drip tray.