Do not use the air purifier outdoors.
Do not use the air purifier in damp rooms.
Do not use the air purifier in conjunction with coloured or oil-based candles, as
they emit soot which can become attached to walls and furniture.
You may experience a small electric discharge when touching the collector.
This is harmless!
You must arrange a ceiling fixture that withstands a minimum weight of 9 kg.
Before installation: Make sure no current exists on incoming wiring.
Connections must be carried out in accordance to wiring regulations.
Hazard: Electric shock.
Before maintenance: Make sure the air purifier is disconnected from the power
supply.
Warning: Never remove the hanger from ion generator under load!
1. Secure the steel bracket into the ceiling (Sketch 1 page 74)
2. Mount transformer onto the steel bracket (Sketch 2-4 page 74)
3. Connect power wiring to terminal block (Sketch 5-6 page 75)
4. Hang the YoYo onto hook of steel bracket (Sketch 7-8 page 75)
5. Mount canopy housing and turn to secure attachment to steel bracket
(Sketch 9-10 page 75)
6. Connect the hanger into the ion generator, snap-fit (click)
(Sketch 11-14 page 76)
Note: LifeAir cannot be held responsible for any damage caused as a result
of failure to follow the recommendations.
INSTRUCTIONS FOR INSTALLATION
ENGLISH
3