OPERATION

CONTROL PANEL

Turning and/or pressing the knob, while quickly pressing
the function buttons are the simple actions that allow the
management of the control panel and the control of the
system.

Display

Timer
Ventilation
Function buttons

KNOB

Press and release the knob to switch the system on; press
the knob ˃2 sec to switch off the system.
Turning the knob allows the programming of the set-point
temperature, choosing between a minimum of 17° C and
a maximum of 30° C.
After pressing the operation buttons, turning the knob
allows the selection of the system operation settings. To
confirm the choice, wait for ~ 2 sec.
DISPLAY
The display usually shows the set-point; it also allows
vision of the operation settings, programmed using the
knob and operation buttons.
IT EN FR DE ES
When the control panel is on, quickly pressing the knob
darkens the display (to prevent disturbing sleep for
instance) but the "on" message remains visible to remind
the user that the system is active.
To return to normal vision, press the knob again.
Knob

DISPLAY - Errors

The display can also show operating errors:
"L.B." (battery saving function): if the battery power falls
below 21.5 V the system switches off and the message
"L.B." (Low Battery) appears on the display; only when
the power returns above 24.0 V does the message "L.B."
disappear from the display, and the system will start
working again. Press and release the knob to switch the
system back on.
Max AC
"HP" (pressure switch intervention): if there is a
problem in the system pressure and the pressure switch
intervenes, the message "H.P." (High Pressure) appears
on the display and the system shuts down. Only when
the problem has been solved and the pressure returns
to normal does the message "H.P." disappear from the
display, and the system will start working again.
"TIME OVER": if the consecutive operating time reaches
its maximum limit (6 h in standard mode and 2 h in MAX
AC mode), the system shuts down and the message
"TIME OVER" appears on the display. Press and release
the knob to switch the system back on.
11/32
Smart
IN
on
L.B.
H.P.
TIME
OVER