COMPRESSED AIR SUPPLY

Clean air in the compressed air system and a largely constant pressure at the required height is
essential for the supply of this tool. The maximum pressure and other values of this
found in the TECHNICAL DATA section. An increase in pressure may be necessary if the length of
the hose or other circumstances lead to a reduction in pressure at the switched-on air tool. It may be
necessary to increase the pressure from 6.2 to for example 7.2 bar, in order to guarantee a pressure
of 6.2 bar on the switched-on tool. Water in the hose and compressor leads to reduced efficiency and
damage to the air tool. Drain the compressed air system before each use.
Use a pressure regulator with pressure gauge if the pressure in the compressed air system is too
high.
RECOMMENDED COMPRESSED AIR SYSTEM
No.
1
Air tool
2
Air hose
3
Quick coupling
4
Oiler
(only required for DL tools with motor)
5
Pressure reducer
LUBRICATION & MAINTENANCE
Before use, add approx. 4 to 5 drops of air tool oil to the air inlet of the unit.
TROUBLESHOOTING
Probable cause
Dirty or blocked air ducts
Insufficient air supply
Leakage
Check O-rings and seals
Tool insert
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Designation
To lubricate this air tool, use only oil which is
suitable for air tools.
Never lubricate the device with engine oil,
transmission oil, power steering oil, etc.
(power
loss)
Lubricate tool, drain compressor and feed lines
Increase air pressure. Ensure that the compressor meets air
volume and pressure requirements
Use Teflon tape to seal all fittings and connectors
Replace worn or damaged parts if necessary
Ensure that the tool can meet the requirements.
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
No.
Designation
6
Drainage/filtering unit
7
Drainage valve
8
Shut-off valve
9
Dryer/filter unit
10
Compressor / 11 Drainage valve
Solution
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
air tool