6. Use the switch-over valve to select the desired operating
mode. To do so rotate the switch-over valve in the
corresponding direction up to the stop (filling mode=to the
right).
A = filling
B = suction
7. Connect the filling machine to the compressed air system.
8. Open the compressed air valve. Now, the pressure in the
tank will rise. At a pressure of approx. 3 bar the safety
valve will open to release the excessive pressure.
9. The filling process starts as soon as you press the trigger
on the filling pistol.
10. The filling process ends as soon as you release the trigger
on the filling pistol.
11. Close the compressed air valve and disconnect the device
from the compressed air system.
12. Carefully open the compressed air valve and release the
pressure from the tank.
13. To disconnect the filling adaptor pull the retaining ring on
the filling pistol in direction of the trigger and pull the
adaptor out of the filling pistol. Proceed accordingly to
disconnect the hose on the filling pistol from the filling
machine.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
A
B
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed