brennenstuhl Multi-Test MT 6 S/2 Instrucciones De Empleo página 9

Ocultar thumbs Ver también para Multi-Test MT 6 S/2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
013109 Multi-Test MT 6 S_2_013109 BA_Multi-Test MT 6_S 01.04.16
MT6 S/2
will start blinking. If there is a wire break, the LED
display will go out. This function can also be used to
find alternating current, e.g. in electrical outlets and
plugs.
Notes:
1) To increase the sensitivity of the tester for
performing the touch-free voltage test, hold the
tester at the point of the probe.
2) The sensitivity can be reduced in high relative
humidity.
3) Perform the test at different points along the wire,
especially if the wire is twisted.
4) The test is not reliable on shielded wires.
Polarity test (direct current 3-36 VDC)
WARNING! Make sure that there is no alternating
current or high voltage current!
The LED will blink at the positive (+) pole.
The LED will not light up on the negative (-) pole.
Conductivity test
WARNING! Make sure that there is no alternating
current or high voltage current!
tivity, the LED will blink. This function can be used to
test, e.g. fuses, light bulbs, etc.
Operating Instructions
(2) touch-free voltage test
(100-250 VAC)
Hold the tester as shown in the
picture and run it slowly along the
wire to be tested. If there is alter-
nating current in the wire, the LED
When testing, a finger of one hand
must touch the screw on the device.
At the same time, the tester's probe
must contact one pole of the
battery and your free hand must
touch the other.
When testing, a finger of one hand
must touch the screw on the device.
At the same time, touch the testing
site with the probe and touch the
object opposite the testing site with
your free hand. If there is conduc-
9

Publicidad

Tabla de contenido
loading

Productos relacionados para brennenstuhl Multi-Test MT 6 S/2

Tabla de contenido