F
B
CH Distance de sécurité
GB Distance to combustible
materials
80
100
130
150
T450
50 mm
T250
20 mm
T200
20 mm
T160
www.poujoulat.fr/dop
D
CH AA Abstand zu brennbaren
NL veiligheidsafstand
B
THERMINOX TI/ZI
Ø
180
200
250
300
350
400
75 mm
30 mm
30 mm
-
CH
F
B
* PDS à n'utiliser qu'en France et en Belgique
Fire-stop and fire rated enclosure arrangement when passing
through two or more floors.
Therminox and fire-stops have been tested to BS476 part 20 to achieve a maximum four
hour rating
FIRE-RATED ENCLOSURE
T250: x = O20
T450: x = G50
INSULATION SLEEVE
COQISOL
AIR-TIGHT CEILING PLATE
PDSE TZ
NON VENTILATED FIRE-STOP
ROS EDP : Ceiling Cover Ring
Werkstoffen
450
500
600
80
100
130
100 mm
40 mm
40 mm
PCF/PDS*
Nota :
T450 France : D=80 mm : Ø80 à Ø450
D
T450
PCF/PDS*
x
14
S
P Distancia de seguridad
CH Distanza di sicurezza
I
THERMINOX TR/ZR
Ø
150
180
200
250
300
350
-
-
-
20 mm
D=100 mm : Ø500 à Ø600
VENTILATED FIRE-STOP
PCF TZ : Ventilated
Fire-stop
VENTILATED FIRE-STOP
PCF TZ : Ventilated
Fire-stop
NON VENTILATED FIRE-STOP
PP MUR : Basic Fire-stop Plate
PPI(G): Adj. Fire-stop Plate
ROS EDP : Ceiling Cover Ring
VENTILATED FIRE-STOP
PCF TZ : Ventilated
Fire-stop
400
450
500
600
30 mm
40 mm
S23-2017 / DI001603