COMPONENTS/MATERIAL

A
A) Instruction manual
B) Screw anchors HILTI HUS3-H 8x55 5 VZ: steel, galvanized
4

DIMENSIONS

[mm]
5

INSTALLATION SUBSTRATE

The basic prerequisite for a correct installation is structurally load-bearing
construction concrete (solid concrete) with a concrete quality of at least
-
C20/25, or
hollow core concrete ceiling C 50/60 B4 with a concrete thickness of
-
25 mm for the minimum hollow core cross-section.
DANGER TO LIFE as a result of installation on an unsuitable
installation substrate.
-
Install INNOTECH "BEF-103" in structurally load-bearing construction
HAZARD
concrete (C20/25) or hollow core concrete ceiling (C 50/60 B4).
-
DO NOT install on screed, levelling concrete, blinding concrete
etc...
In case of doubt, have the installation substrate examined by a statics
-
engineer or by the manufacturer.
The tensioned steel reinforcements of the hollow core ceiling must not
be damaged. In case of doubt, contact the manufacturer.
B
C 20/25
O
BEF-103 / Version 1.0 / www.innotech-safety.eu