TIMER TYPES
1 - Cyclic through voltage ON/OFF (Equivalent to I-10, I-11 et I-12)
Connecting the power supply, the relay will be activated during the ON time and it will be deactivated during the OFF time. At the end of the OFF time,
the ON time start again.
2 - Cyclic through voltage OFF/ON
Connecting the power supply, the relay will be activated during the OFF time and it will be deactivated during the ON time. At the end of the ON time,
the OFF time start again.
3 - Cyclic through push button ON/OFF
Closing the START button, the relay will be activated during the ON time. At the end of the ON time, the relay will be deactivated during the OFF time.
At the end of the OFF time, the ON time start again.
4 - Cyclic through push button OFF/ON
Closing the START button, the relay will be activated during the OFF time. At the end of the OFF time, the relay will be deactivated during the ON
time. At the end of the ON time, the OFF time start again.
5 - Timing with Delay through voltage (Equivalent to I-33 and I-34)
Connecting the power supply, the OFF timing will be activated without connecting the relay. At the end of the OFF time, the relay is connected during
the ON time.
6 - Timing with Delay through push button (Equivalent to I-33 and I-34)
Closing the START button, the OFF timing will be activated without connecting the relay. At the end of the OFF time, the relay is connected during the
ON time.
7 – Timing with Delay and Reactivation OFF through push button
Closing the START button, the OFF timing will be activated without connecting the relay. At the end of the OFF time, the relay is connected during the
ON time. If during the ON timing the push button is closed, the timing is reset and the OFF time start again. It doesn't affect the ON time.
8 – Timing with Delay and Reactivation ON through push button
Closing the START button, the OFF timing will be activated without connecting the relay. At the end of the OFF time, the relay is connected during the
ON time. If during the ON timing the push button is closed, the timing is reset and the ON time start again. It doesn't affect the OFF time.
1 – Cyclique par tension ON / OFF (Équivalent I-10, I-11 et I-12)
En connectant l'alimentation le relais sera activé pendant le temps ON. A la fin du temps ON, le relais se désactivera durant le temps OFF. A la fin du
temps OFF, le temps ON recommence à nouveau.
2 – Cyclique par tension OFF / ON En connectant l'alimentation le relais sera activé pendant le temps OFF A la fin du temps OFF, le relais se
désactivera durant le temps ON. A la fin du temps ON, le temps OFF recommence à nouveau.
3 - Cyclique par bouton poussoir ON/OFF
En fermant le bouton START le relais sera activé durant le temps ON. A la fin du temps ON, le relais se désactivera durant le temps OFF. A la fin du
temps OFF, le temps ON recommence à nouveau.
4 - Cyclique par bouton poussoir OFF/ON
En fermant le bouton START le relais sera activé durant le temps OFF. . A la fin du temps OFF, le relais se désactivera durant le temps ON. A la fin
du temps ON, le temps OFF recommence à nouveau.
5 - Temporisation avec Retard par tension (Équivalent I-33 et I-34)
En connectant l'alimentation la temporisation OFF commence mais sans connecter le relais. A la fin du temps OFF le relais est connecté durant le
temps ON.
- TYPES DE TEMPORISATEUR - TIPOS DE TEMPORIZADOR
FUNCTIONS
Cyclic / Voltage / ON/OFF
Cyclic / Voltage / OFF/ON
Cyclic / Push button / ON/OFF
Cyclic / Push button / OFF/ON
Timered / With Delay / ON/OFF
Timered / With Delay / OFF/ON
Reactivation – OFF Delalay / Push button
Reactivation – ON Delalay / Push button
www.cebek.com
-