Messages
85
Mode button:
Switching between parameters LED 80 to
LED 83
7 sec. Press to switch the display (84) be-
tween right- and left-hand mode. A point
is shown in the right, bottom of the display
22 Messages
22.1 Error messages
Faults can be reset by switching off
i
and on again.
Code
Fault
E01-01 Excess temperature
E01-02
E01-05
E02-00 Overvoltage, primary Mains voltage too high
E02-01
E02-02
E04-05 PFC error
E06-00 Overvoltage second-
ary
E07-01 Internal EEProm fault
E10-00 Fault in torch
E11-00 Fault in remote con-
trol
E12-00 Fault in Power unit
E13-01 Thermal sensor
E13-02
04.19
Possible cause
The device has overheated, the
permitted switch-on time was
exceeded
Internal working voltage too
high
Internal mains control not work-
ing
Initial voltage too high
Internal accummulator faulty
Torch or connections defective
Defect in remote control or
remote control socket
Power section start-up faulty
Internal temperature sensor
defective
909.4169.9-03
as index.
The "Mode" button is unlocked for 15 sec.
by pressing it for 2 sec. (when the "Power-
master LED lock" (PLL) secondary parameter
is activated).
Please take note of the fault infor-
mation.
Rectification
Allow switched-on machine to cool
down for a few minutes.
Check mains voltage, test device on
another power socket.
Switch the equipment off and on
again. Inform the customer service
in the event of a repeated or perma-
nent fault message
Check the work piece. Inform the
customer service in the event of a re-
peated or permanent fault message
Switch the equipment off and on
again. Inform the customer service
in the event of a repeated or perma-
nent fault message
Check or replace torch
Check or replace the remote control
Switch the equipment off and on
again. Inform the customer service
in the event of a repeated or perma-
nent fault message
- 47 -