EC-Declaration of Conformity
We declare under our sole responsibility that the product
described under "Tool Specifications" complies with all
applicable provisions of the directives 2009/125/EC
(Regulation 1194/2012), 2011/65/EU, 2014/30/EU,
2006/42/EC including their amendments and is in conform-
ity with the following standards: EN 60745-1,
EN 60745-2-2, EN 50581.
Technical file (2006/42/EC) at:
Adolf Würth GmbH & Co. KG, Abt. PPT
Reinhold-Würth-Straße 12–17
74653 Künzelsau
GERMANY
www.wuerth.de
Frank Wolpert
Dr.-Ing. Siegfried Beichter
General Manager
General Manager
Künzelsau: 16.06.2016
Removing the Battery (see figure A)
Note: The battery supplied is partially charged. To ensure
full capacity of the battery, completely charge the battery in
the battery charger before using your power tool for the first
time.
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging procedure
does not damage the battery.
The Lithium-Ion battery is protected against deep discharging.
When the battery is empty, the machine is switched off by
means of a protective circuit: The inserted tool no longer
rotates.
 Do not continue to press the On/Off switch
after the machine has been automatically
switched off. The battery can be damaged.
To remove the battery 7 press the unlocking buttons 6 and
pull out the battery downwards. Do not exert any force.
Observe the notes for disposal.
Changing the Tool (see figure B)
 Before any work on the machine itself (e. g.
maintenance, tool change, etc.) as well as dur-
ing transport and storage, remove the battery
from the power tool. There is danger of injury when
unintentionally actuating the On/Off switch.
Inserting
Pull the locking sleeve 3 forward, push the insert tool to the
stop into the tool holder 2 and release the locking sleeve 3 to
lock the insert tool.
Use only screwdriver bits with ball catch 1 (DIN 3126-E6.3).
Other screwdriver bits 13 can be used with a universal bit
holder with ball catch 12.
Removing
Pull the locking sleeve 3 forward and remove the insert tool.
Method of Operation
The tool holder 2 with the tool is driven by an electric motor
via a gear and impact mechanism.
The working procedure is divided into two phases:
Screwing in and tightening (impact mechanism in
action).
The impact mechanism is activated as soon as the screwed
connection runs tight and thus load is put on the motor. In this
instance, the impact mechanism converts the power of the
motor to steady rotary impacts. When loosening screws or
nuts, the process is reversed.

Starting Operation

Inserting the Battery
 Use only original Würth lithium-ion batteries
with the voltage listed on the nameplate of
your power tool. Using other batteries can lead to
injuries and pose a fire hazard.
Note: Use of batteries not suitable for the machine can lead
to malfunctions of or cause damage to the power tool.
Set the rotational direction switch 8 to the centre position in
order to avoid unintentional starting. Insert the charged bat-
tery 7 into the handle so that it can be felt to engage and
faces flush against the handle.
Reversing the Rotational Direction
(see figure C)
The rotational direction switch 8 is used to reverse the rota-
tional direction of the machine. However, this is not possible
with the On/Off switch 9 actuated.
Right rotation: For driving in screws and tightening nuts,
press the rotational direction switch 8 through to the left stop.
Left Rotation: For loosening and unscrewing screws and
nuts, press the rotational direction switch 8 through to the right
stop.