Insert Battery - LaserLiner StarFinder Manual Del Usuario

Ocultar thumbs Ver también para StarFinder:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

Insert battery

1
Open the battery compartment on the housing's rear side and insert
a 9 V battery. Correct polarity must be observed. See illustration on
previous page.
Operation
2
Switch the device on (Button 6). AutoShutOff: The device will auto-
matically switch itself off about 2 minutes after the last measurement.
Select measurement mode
3
Select STUD-SCAN or AC-SCAN with the Mode button (6). The mode
indicators (3) will show the presently set mode. For safety reasons,
the AC voltage warning is always active: The „Voltage (AC) found"
LED (5) lights up if a live line is located within the measuring range.
Measuring in STUD-SCAN mode
4
For electronically detecting studs and joists (wood and metal)
in dry walls (behind plaster fibreboard, wooden panels and other
non-metallic panelling). Use the SET button (4) to adjust the
measuring depth.
– Select STUD-SCAN (button 6). Select "Normal" (SET button).
This setting is ideal for plaster fibreboard panels installed in
one thickness (max. 2 cm).
– Select "Deep" (SET button) for two plaster fibreboard panels
installed on top of each other (max. 4 cm).
– Select "Super-Deep" (SET button) for thick wooden panels and
floor constructions (parquet etc.), max. measuring depth 6 cm.
– Place the tool against the wall.
– LED CAL (3) flashes: Press the calibration button (7) and wait until
calibration is completed. CAL OK: LED cal (3) lights permanently.
– Move the tool slowly across the surface.
Slide the tool sideways across the wall. When the
maximum display appears, you have reached the
edge of the stud.
08
GB
Then scan for the other
edge of the stud.

Publicidad

Tabla de contenido
loading

Tabla de contenido