Summary
The Wall Mounted Adaptor (SADT-100WM) is used for the
installation of the Smartdome Camera (indoor or outdoor housing)
on walls.
Precautions Before Installation
•
Make sure that the proposed location can support the combined weights of the Wall
Mounted Adaptor, Outdoor Housing and Smartdome Camera (about 8 kg).
•
This product is designed to use M10 anchor bolts or nuts.
•
When installing the product on a concrete wall, use M10 anchor bolts/nuts together
with plain and spring washers.
•
Each anchor bolt must be capable of withstanding an extraction force of 700 kg.
•
When installing the product outdoors, use interlocking devices made of stainless steel.
•
The Wall Mounted Adaptor may be installed directly on a wall or in conjunction with
the Corner Mounted Adaptor (SADT-110CM) or the Pole Mounted Adaptor
(SADT-100PM), in which cases a PG-13.5 cable gland should be used.
•
This goods should only be installed by a qualified technician using approved materials
and wiring practices in accordance with national, state, and local electrical code.
1
Installation
Select a location that will support four times the total weight of the
1
product to be installed (about 32 kg).
Use the Back Plate to mark the positions of the M10 anchor
2
bolts/nuts on the wall, drill the holes and install the anchor
bolts/nuts.
• When installing in the corner of a wall, use the Corner Mounted Adaptor
(SADT-110CM). When installing on a pole, use the Pole Mounted Adaptor
(SADT-100PM).
3
If the cable pipe is installed inside the wall:
1) Pull the power cable, video-out cable and communications cable out through
the holes of the Back Plate and Wall Mounted Adaptor. Take care not
toavoid damageto the cable sleeving.
•
When installing with the Corner Mounted Adaptor or the Pole Mounted
Adaptor, use a PG-13.5 Cable Gland for watertightness.
If the cable pipe is installed on the wall:
1) Make a hole of 21mm in diameter on the outside of the pipe (on the side and
near the tip) and install a PG13.5 cable gland.
2) Pull the cables out to the Wall Mounted Adaptor through the cable gland.
•
Positions for the hole (unit: mm)
GB