Descargar Imprimir esta página

Technical Specification - Dedicated Micros Dennard drx 400-II Manual De Instalación

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2. Technical Specifications
Power Requirements:
230 volts 50/60Hz (options are available for 24Vac and 110Vac supply)
IEC connector provided (screw terminals with 24Vac supply option)
Maximum Load:
5 amp at 230 volts
Receiver Current Draw:
6VA maximum
Fuse:
The transformer contains a none re-setable thermal fuse in series with the primary windings.
Supply
230
230
110
110
24
Outputs:
8 single-pole changeover relays (snubbed):
1. Left motor
2. Right motor
3. Up motor
4. Down motor
5. Autopan (interlocked with pan left/right)
6. Lights (1000W maximum)
7. Wash
8. Wipe
Facilities/Options:
Unit auto-tunes to the coaxial telemetry signal
LED readout for continual system status
Diagnostic test switch (SW8) activates each function for two seconds in turn; see Table for test
sequences.
Video launch amplifier provided with Gain and Lift controls
Camera power outlet provided.
Colour-coded outlets: Live, Neutral and Earth
24-volt option available from factory; plugs into J5 (pre wired)
Dennard drx 400-II Installation Manual
F2: Auxiliary output fuse
Output
230
24
110
24
24
Fuse F2
5A T
315mA T
5A T
630mA T
5A T
Page. 3

Publicidad

loading