UNDERCOUNTER INSTALLATION
Setting tool
Anchor
Marble
Foam padding
Clamp
Apply sealant
Wood
Anchor
screw
screw
• Cut out the opening by carefully following the
pencil line traced from the template.
NOTE: The screws and anchors provided
should be used on countertops with a
minimum 1" (2.5 cm) thickness. For thinner
countertops, use appropriate anchors and
fasteners (not provided).
For Wood Countertops
• Mark and pre-drill the wood screw holes at
the locations shown on the template.
• Waterproof any exposed areas of wood.
For Marble/Stone Countertops
• Position the countertop upside down on foam
padding to protect the surface. Mark and drill
3/8" holes 5/8" (1.6 cm) deep at the
locations shown on the template.
• Use a setting tool and hammer to secure
the anchors.
For All Undercounter Installations
• If the countertop has not been installed,
install it at this time.
• Drill the faucet holes according to the faucet
installation instructions.
• Install the faucet to the countertop according
to the faucet manufacturer's instructions.
• Install the drain to the lavatory according to
the drain manufacturer's instructions.
NOTE: Do not use adhesives or adhesive
sealants.
• Apply a continuous bead of quality sealant
to the top surface of the lavatory rim where it
will contact the countertop.
CAUTION
Risk of personal injury or
product damage.
Handle with care. Product can break,
chip or cause injury if handled carelessly.
Get help lifting the lavatory.
• For marble countertops, install the lavatory
to the countertop with the clamps and screws
provided. For other countertop materials,
refer to the countertop manufacturer's
instructions for recommended fasteners.
• Position the lavatory squarely under the
cutout before tightening the clamps. Draw
the lavatory rim up against the countertop
until it is snug. Do not overtighten.
• Immediately wipe away any excess sealant
and fill any voids as needed.
• Allow the sealant to set for 30 minutes before
proceeding.
• Connect and tighten the trap to the drain,
and complete the water supply connections to
the faucet according to the instructions
packed with the faucet.
• Run water into the lavatory and check for leaks.
• Clean up with a non-abrasive cleaner.
3
• For ADA installation, please follow
recommended rough-in dimensions below.
Finished
Wall
34"
8"
(864mm)
(203mm) min
Knee
27"
Clearance
(686mm) min
11" (279mm)
Toe Clearance
9" (229mm) min
Recommended ADA Installation
TILE-INSTALLATION
Sink
Grout
Tile
Mortar or
adhesive
Water resistant underlayment or
backing material 3/4" minimum"
• C
ut out the opening by carefully following the
p
encil line traced from the template.
• D
rill the faucet holes according to the faucet
in
stallation instructions.
•
Measure and compare the thickness of
th
e lavatory rim and tile. The lavatory rim
th
ickness is 3/8" (1 cm) plus or minus
1
/32" (1 mm). Because of the varying
th
ickness of the tile and lavatory, or if
a
dhesive or mortar bed installation is used,
make allowances to shim the lavatory, or
r
oute the underlayment as required.
CAUTION
Risk of personal injury or
product damage.
Handle with care. Product can break,
chip or cause injury if handled carelessly
Get help lifting the lavatory.
NOTE: Apply additional sealant if using shim
• Carefully re-position the lavatory. Press
down firmly.
• Tile and grout to allow an acceptable spa
between the tile and lavatory.
• Use sealant in the space between the lava
and tile.
• Install the faucet to the countertop accordi
to the faucet manufacturer's instructions.
4
.
s.
ce
tory
ng