Thermostatically Controlled Heating Element
Recommended Wiring Diagram and
Installation Instructions
Aerofiner II
Air Dryer
#10 Screw
Black
Ground
Note: The RN977 and RN978 thermostatically controlled heating
elements are set to provide heat when the temperature falls below
+30°F and will automatically shut off at +45°F.
Install the heating element by inserting the heater tube into the
"HEAT" port on the bottom of the AREOFINER II unit. Secure the
cartridge with the self-tapping screw provided. Slide the boot over
the leads and push onto the thermostat. A lead wire* can then be
attached, from the vehicle electrical system to the red heater lead.
The black lead must be secured to a good vehicle ground.
Bottom view of
Aerofiner II Unit
showing heater port.
* Lead wire and ground wire are not provided with the heating element. It
is suggested a minimum 18 AWG Gauge stranded wire be used for
durability in service.
Commercial Vehicle Systems
Haldex Brake Products Corporation
10707 N.W. Airworld Drive
Kansas City, MO 64153-1215
Phone: (816) 891-2470
Fax: (816) 801-4198
L31096 US 3/07 2M ART (Last Rev 03/02)
Ignition
Switch
Ground
Red
Optional
Battery
Wiring
Installation
Pilot Hole
Heat Port
Haldex Limited
525 Southgate Drive, Unit 1
Guelph, Ontario Canada N1G 3W6
Phone: (519) 826-7723
Fax: (519) 826-9497
www.haldex.com - www.hbsna.com
Installation
Guide
L31096
Rev. 03/02
AEROFINER II
AIR DRYER
HEATING ELEMENTS
RN975/RN976
RN977/RN978

Publicidad

loading

Resumen de contenidos para Haldex AEROFINER II

  • Página 1 AIR DRYER The black lead must be secured to a good vehicle ground. HEATING ELEMENTS Bottom view of Pilot Hole Aerofiner II Unit RN975/RN976 showing heater port. Heat Port RN977/RN978 * Lead wire and ground wire are not provided with the heating element. It is suggested a minimum 18 AWG Gauge stranded wire be used for durability in service.
  • Página 2 +32°F. A heating turning off the power when the heating element is not needed. element will keep the moisture in the Aerofiner II purge valve from freezing, thus allowing proper valve operation. Install the heating element by threading the heater tube into the “HEAT”...
  • Página 3 Del Secador de Aire Vista inferior de la Agujero piloto unidad Aerofiner II Aerofiner II que muestra Puerto Termico el puerto calefactor. RN975/RN976 * El hilo de plomo conductor y el hilo de toma de tierra no se RN977/RN978 suministran con el elemento calefactor.
  • Página 4 0ºC (+32ºF). Un elemento calefactor mantendrá la humedad desconectar la energía eléctrica cuando no se necesita. necesaria en la válvula de purga del Aerofiner II para que no se congele y la válvula puede funcionar correctamente. Instale el elemento calefactor roscando el tubo calefactor en el puerto "HEAT"...

Este manual también es adecuado para:

Rn975Rn976Rn977Rn978