5. SETUP INSTRUCTIONS POOLDOSE SYSTEM
1
2
Program Setup – Press
At the entry of each menu item, the parameter can be directly modified using the arrow keys (
Confirmation of the current setting and switching to the next item is done by pressing the
The menu has a circular structure: once you arrive at last item, the confirmation of the parameter set by
pressing
, determines the return to the first menu item.
Language
1
Setpoint
2
Type
dosing
3
_
Time
on
4
= 30seconds (range from 1 to 360 seconds)
_
Time
off
5
= 60seconds (range from 1 to 360 seconds)
_
Advanced menu
6
Select Measure
4.1
Circulation pump
4.2
Temp
4.3
.
Temp
4.4
.
OFA
OFF
4.5
_
Input Flowrate
4.6
§ Pulse/ liter 1:1
§ Unit measure m³, l.
Calibration
4.7
§ Two points
§ Single point
§ Referece
Peristaltic dosing type
4.8
§ On/Off
§ Timed
§ Prop
§ Off
Aux Relay
4.9
0000138981
3
4
5
for 5 seconds
– It is possible to select between 5 available languages: EN, FR, IT, DE, ES
– 7.4pH (5-9pH) / 700mV (300-900mV)
– Acid (Acid/Alka) / Low (Low/High)
– (pH/ORP)
– (Enabled/disabled)
compensation
– (Auto/Manual 25°C, range 15...45°C)
probe Calibration
– Reference (PT100 sensor) or Disabled
– (0-60min.)
(Off/On)
1) Button to increase the value
2) Button to decrease the value
3) Button Menu/Esc
6
4) Button Cal/OK
5) Button to set the setpoint
6) Digital display
rev. 1.0
EN
and
).
button.
* Timed dosing only
4