Technical Data; Specified Conditions Of Use; Operating Times; Residual Risks - Gude GBM 130 Traducción Del Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69

Technical Data

Concrete Mixer
Art. No
Mains voltage / Mains frequency
Rated power
Protection class
Degree of protection
max. Drum capacity
Mixer drum speed
Drum arrest
Ø-Handwheel
Overall dimensions LxWxH in mm: App.
270x295x200
Weight
Noise details
Sound pressure level L
pA
Distance 1 m, Height above the earth 1,55 m
Measured sound power level L
Guaranteed sound power level L
max. Drum capacity, sand / granulate 0-3 mm, Humidity 4-10% max.
Measured according to EN ISO 3744; Uncertainty K = 3 dB (A), Wear ear protectors!
Read and understand the operating
instructions before using the
appliance. Familiarise with the
control elements and how to use the appliance
properly. Abide by all the safety measures stated in
the service manual. Act responsibly toward third
parties.
The operator is responsible for accidents or risks to
third parties.
Conduct a first-aid procedure adequate to the
injury and summon qualified medical attendance as
quickly as possible. Protect the injured person from
further harm and calm them down. For the sake of
eventual accident, in accordance with DIN 13164,
a workplace has to be fitted with a first-aid kit.
It is essential to replace any used material in the
first-aid kit immediately after it has been used.
In case of any doubts about connection and operati-
on refer please to our customer center

Specified Conditions Of Use

The concrete mixer has been designed to be used
both in house and in the garden exclusively for con-
crete and mortar production.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
GBM 130
55451
230 V ~ 50 Hz
550 W
II
IP44
130 l
35 min
18-fach
545 mm
1.200 x 710 x 1.350 mm
49 kg
73,5 db(A)
93 dB(A)
WA
95 dB(A)
WA
GBM 160
55456
230 V ~ 50 Hz
800 W
II
IP44
160 l
29,5 min
-1
16-fach
550 mm
1.280 x 840 x 1.345 mm
67 kg
73,5 db(A)
93 dB(A)
95 dB(A)

Operating times

According to ordinance on protection against noise
by machines from September 2002, concrete mixers
must not be put into operation on Sundays and
holidays and on working days between 8.00 PM and
7.00 AM in territories specified by the master plan
as a clean living environment, in general and special
residential areas, small settlements, in special purpose
territories used for holiday purposes, in territories
with spas and clinics, hotels / accommodation units
and in territories with hospitals and nursing homes.
Regional noise protection regulations must also be
complied with.

Residual risks

There can still be some residual risks given by the
machine design despite using the machine in accor-
dance with all the respective safety regulations.
Residual risks may be minimised by following the
safety instructions and use as designated provisions
and the Operating Instructions.
Caution reduces the risk of personal injury and
material damage.
ENGLISH
-1
29

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gbm 1605545155456