GB
3
4
1. ON/OFF BUTTON
Press to switch the dehumidifi er on and off . The indicator light to the left of the ON/OFF button remains lit when the appliance
is functioning and unlit when the appliance is off .
2. MODE BUTTON
Press to select the desired operating mode: STANDARD MODE or CONTINUOUS MODE. STANDARD MODE: the appliance
functions until the desired humidity level is reached.
CONTINUOUS MODE: the appliance functions at the maximum dehumidifi cation level until the tank fi lls up.
In this mode, the '+' and '-' control buttons are not enabled ('cont' indicator on).
3. TIMER button
Press to set the start delay when the appliance is off , or the switch-off delay when it is on. The indicator light to the left of the
timer button will light up.
Press or hold the '+' and '-' control buttons to set the desired delay: 30 min (0.5 hours) increments occur between 0 and 10
hours, and 1-hour increments between 10 and 24 hours.
Restore the delay to 0.0 or switch off the appliance to cancel the timer function.
4. TURBO button
Press to select the desired ventilation speed between normal and laundry room function (the indicator light turns on).
5. HUMIDITY SETTING BUTTONS
The desired relative humidity level can be set to between 35% (minimum) and 80% (maximum), with 5% increments each time
the '+' and '-' control buttons are pressed. When the set humidity level is reached, the compressor stops and the fan contin-
ues to turn for 3 minutes. The humidity setting buttons are disabled in the continuous mode.
6. DISPLAY
In the standard mode, the display visualises the desired level of humidity while it is being set with the buttons. Once set, the
display will visualise the percentage of relative humidity in the room. In continuous mode, the display will visualise the per-
centage of relative humidity in the room.
AUTO-RESTART
This function enables the dehumidifi er to restart, after a blackout, from the last stored settings.
ANTI-FROST FUNCTION
Prevents the evaporator from frosting, thereby extending the dehumidifi er's life and enhancing energy saving. When this function is ac-
tive, the fan continues to turn while the compressor stops and 'P1' appears on the display.
TANK FULL STOPPAGE
The dehumidifi er stops when the condensate collection tank is full or incorrectly positioned. 'P2' will appear on the display
and the 'full' indicator light turns on.
IMPORTANT: When the compressor stops, it is necessary to wait 3 minutes before it restarts.
CAUTION
Do not touch the selector with wet hands (risk of personal injury due to electrocution).
Do not start or stop the appliance by simply plugging it into the power socket or unplugging it (risk of personal injury due to
electrocution).
Avoid prolonged direct exposure to the air fl ow (risk of personal injury due to sensitisation of the skin).
16