1. Remove the retaining ring, pin, and spacers (Items 4, 5, & 6) from the lift arm.
2. Loosen the bolt (15) and remove the tag from the load block (18).
3. Install the hydraulic unit (3) into the load block until the piston bottoms, with the recessed area in the piston
pointing up toward the bolt. See Figures 1 and 2.
IMPORTANT: To prevent damage to equipment and to make the clutch handler function correctly,
the bolt must rest in the recessed area of the piston.
Load Block
Figure 1
4. Use a 7/16" wrench to snug the bolt against the
piston. See Figure 3.
5. Align the mounting holes in the hydraulic unit with
the holes in the clutch handler frame. NOTE: Use
the hydraulic control valve to move the piston in/out
for easier alignment.
6. Insert the pin (4) through the frame, assemble one
spacer (5), continue pushing the pin through the
hydraulic unit, assemble other spacer, and push the
pin out through the frame. Attach a retaining ring (6)
to each end of the pin. See Figure 4.
7. Install casters (8) to the frame with lockwashers and
nuts (13 & 14) assembled on top of the frame. Use
an 11/16" wrench to tighten the nuts.
8. Thread the handle into the head of the hydraulic
unit.
9. Close the control valve, and pump the handle to
raise the head assembly and lift arm.
10. Install the splined shaft (1) using the hair pin (2)
provided.
© SPX Corporation
Assembly Instructions
(Item numbers refer to the parts list illustration.)
Bolt
(with tag removed)
Recessed
Area
Piston
from
Hydraulic Unit
Load
Block
Figure 2
Figure 3
Figure 4
Form No. 107299
Hydraulic
Unit
Hydraulic Control Valve
Rev. C 7-19-04 Sheet
2 of 3

Publicidad

Tabla de contenido
loading

Tabla de contenido