120 Volt, 30 Amp Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect
a 3-wire cord set rated for 125 Volt AC loads at
30 Amps (or greater) to the plug.
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 3600 watts (3.6 kW)
of power at 30 Amps. The outlet is protected by a
30 Amp push-to-reset circuit breaker.
120/240 Volt, 30 Amp Receptacle
Use a NEMA L14-30 plug with this receptacle.
Connect a suitable 4-wire grounded cord set to the
plug and to the desired load. The cord set should be
rated for 250 Volt AC loads at 30 Amps (or greater).
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 3600 watts (3.6 kW)
of power at 30 Amps or 240 Volt AC, 60 Hz, single
phase loads requiring up to 7200 watts (7.2 kW) of
power at 30 Amps. The outlet is protected by a
30 Amp push–to–reset circuit breaker.
12 Volt DC, 10 Amp Receptacle
The 12 Volt DC receptacle allows you to recharge a
12 Volt automotive or utility style storage battery with
the battery charge cables provided.
This receptacle can not recharge 6 Volt batteries and
can not be used to crank an engine having a
discharged battery. See the section "Charging a
Battery" (page 11) before attempting to recharge a
battery.
120/240 Volt AC, 50 Amp Receptacle
Use a NEMA 14–50 plug with this receptacle. Connect
a 4-wire cord set rated for 250 Volt AC loads at
50 Amps to the plug.
Use this receptacle to operate 240 Volt AC, 60 Hz,
single phase loads requiring up to 10,000 watts
(10.0 kW) of power.
CAUTION!
Although this outlet states it has a
240 Volt 50 Amp rating (up to 12,500 watts), the
generator is only rated for 10,000 watts.
Powering loads that exceed the wattage/
amperage capacity of the generator can
damage it and cause serious injuries.
7