2. Declaration of Conformity
2. Declaration of Conformity
3. Warranty Period
4. Service
5. Description
6
The manufacturer of this product declares that this product is in accordance with the following
standards:
EMC Directive 2004/108/EC:
EN55103-1:2009*
EN55103-2:2009
EN61000-3-2:2006/A2:2009
EN61000-3-3:2008
*This Product meets the immunity requirements for E2 class EN55103-1 directive.
Initial turn on inrush current Entero
Inrush current after 5 seconds AC mains interruption Entero
Vac / 50 Hz)
Low Voltage Directive 2006/95/EC (Safety):
EN/IEC60065:2002 (7th edition)
RoHS2 Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the
restriction of the use of certain hazardous substances in electrical and electronic equipment.
When used in combination with the Entero
accordance with the following standard:
CPR Construction Products Regulation 305/2011 EU:
EN54-16:2008
The Entero
ESA power amplifier comes with a 5-year transferable limited warranty.
®
If you experience problems with your Entero
dealer. The dealer will verify any defects and arrange for service.
The Entero
ESA Emergency System Amplifiers ESA-8125 and ESA-8250 are professional
®
multichannel power amplifiers, throughout this document referred to as 'ESA 8125', 'ESA 8250'
and 'ESA amplifiers'. The ESA amplifiers can be used in fixed installations in low impedance & 50 V
(100 V bridged) operation both can also be used in Voice Alarm systems. The amplifiers deliver
8x125 Wrms@50 V (ESA 8125) and 8x250 Wrms@50 V (ESA 8250). In bridge mode they deliver
4x250 Wrms@100 V (ESA 8125) and 4x500 Wrms@100 V (ESA 8250), both without using 100 V
output transformers. See chapter 9 'Technical Specifications' for low impedance specifications.
Both amplifier models include 8 high efficient half bridge Class D output stages and a Switch
Mode Power Supply (SMPS) which include both a 230 Vac mains input and a 48 Vdc battery
input (the ESA-8250 includes 2 power supplies, 1 for Ch.1/2/7/8 and 1 for Ch.3/4/5/6). Each
channel includes balanced input connections with input gain control, a limiter to reduce severe
clipping & overload and each channel features an EQ card slot for Bose
ESA 8125 / 8250: 20 A / 25 A (230 Vac / 50 Hz).
®
ESA 8125 / 8250: 10 A / 15 A (230
®
ESC emergency system controller, the product is in
®
ESA power amplifier, contact your authorized
®
series II-s EQ cards.
®