6
GENERAL DESCRIPTION
6.1
Dust Free Industrial 8500 for industrial extraction of dust and
fine particulates
This air cleaner is able to capture the dust and fine particulates released in
many industrial processes, which would normally remain in the room, with a
very high efficiency.
6.1.1
Method of extraction of the polluted air
•
DFI 8500: through intake grille
6.2
Operation
The polluted air is sucked in and first reaches the main filter (fig. 3). All large
particles are captured in this main filter.
The second filter in the package is the final filter (fig. 3).
Repairs may only be carried out by Euromate or by persons authorised by
Euromate. A maintenance contract is also possible.
7
OPERATION / STATUS
The main switch is used to switch the power on and off.
The 'play' button is used to switch the device on.
The LED ring around the 'play' button indicates the status of the machine.
This is done using different colours:
Colour code
Description
White
Standby (fan off )
Blue
Fan constant speed
(Fixed control voltage)
Green
Fan variable speed (constant flow)
Blue flashing
Constant + timer
Green flashing
Pressure controlled + timer
Green/White flashing
Boost (temporarily increased flow)
Red
Error
Orange flashing
Replace filter soon
Orange
Replace filter
Red/White
Connection lost
Purple flashing
Localising
White/purple
Calibration
8
DIMENSIONS
8.1
Dimensions DUST FREE INDUSTRIAL 8500
See figure 2.
9
MAINTENANCE
If the following simple maintenance and cleaning operations are carried out
with due care and at the specified intervals, any problems can often be
detected and corrected before they lead to an interruption of service. The
maintenance intervals may vary from those specified, depending on the
specific working and operating conditions. It is therefore recommended that,
in addition to the periodic maintenance indicated here, the machine be
subjected to a thorough, comprehensive annual inspection. Please contact
your supplier for more information.
Standard and/or Touch control
Standard/Touch Control
Standard/Touch Control
Standard/Touch Control
Touch Control
Touch Control
Touch Control
Standard/Touch Control
Standard/Touch Control
Standard/Touch Control
Touch Control
Touch Control
Standard/Touch Control
WARNING
Overdue maintenance can lead to fire.
WARNING
Always turn the machine OFF before using the power outlet on
the unit. Observe the maximum wattage.
WARNING
Always turn the machine OFF and unplug it from the mains
socket before carrying out the work described below. First read
the maintenance instructions at the beginning of this manual.
9.1
Periodic maintenance
The maintenance work indicated with a [1] in the table below may be
carried out by the user; all other work may only be carried out by
qualified personnel.
Action
Clean the outside of the machine with a mild detergent.
Clean the inside of the machine and remove the dust/
grease from the filter compartment.
Clean or replace the bag filter and/or compact filter(s).
Check the filters for damage.
9.2
Replacing the filters
Replace the filters:
•
in the event of damage
•
as soon as the extraction capacity becomes inadequate
Because the nature and degree of contamination greatly depend on factors
such as the exact application, humidity level, intensity of use etc., you will
have to determine the necessary replacement frequency based on
experience. Nevertheless, the filters should be checked regularly (every two
weeks to every two months).
WARNING
Contaminated filters often contain dust and dirt particles that
can pose a threat to health when inhaled. Therefore, wear a
proper, approved face mask when cleaning the filters.
9.2.1 Removing the filters
•
Switch the machine off with the main switch (fig. 4).
•
Release the latches and open the grille.
•
Remove the filter or filters.
9.2.3 Replacing the filters
•
Bag filter
•
Compact filter
User Manual Dust Free Industrial 8500