9
POWER-SELECTION OPERATION
This function is used when its circuit breaker is shared with other electrical
appliances. It limits the maximum current/power consumption to 100%, 75%
or 50%. The lower the percentage, the higher the saving and also the longer
the compressor lifetime.
Press
POWER-SEL
: Select
(for 100%),
● When the level is selected, PWR-SEL level fl ashes on LCD display for 3
seconds. In case of 75% and 50% level, number "75" or "50" also fl ashes
for 2 seconds.
● Due to the reason that POWER SELECT FUNCTION limits the maximum
current, inadequate cooling capacity may occur.
10
TIMER OPERATION
Set the timer when the air conditioner is operating.
Setting the ON Timer
1
Press
: Set the desired ON
timer.
2
Press
: Set the timer.
3
Press
: Cancel the timer.
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
1
Press
: Set the ON timer.
2
Press
: Set the OFF timer.
● During daily timer is activating, both arrows ( , ) are indicated.
Note:
● Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
● The setting will be saved for the next same operation.
11
DISPLAY LAMP BRIGHTNESS ADJUSTMENT
To decrease the display lamp brightness or turn it off.
1. Press and hold
for 3 seconds until brightness level (
or
) is shown on remote control LCD then release the button.
2. Press
or
Rise
Decrease
Remote control
Operation display
LCD
Lamp illuminates full brightness.
Lamp illuminates 50% brightness.
Lamp illuminates 50% brightness and the
operation lamp is turned off.
All lamps are turned off.
● In the examples of
and
, the lamp illuminates for 5 seconds before
going off.
(for 75%),
(for 50%)
Setting the OFF Timer
Press
: Set the desired
OFF timer.
Press
: Set the timer.
Press
: Cancel the timer.
3
Press
.
4
Press
button during
the ( or ) mark fl ashing.
,
,
to adjust brightness in 4 levels.
Brightness
100%
50%
50%
All turned off
12
TEMPORARY OPERATION
In case of the misplaced or discharged remote control
● Pressing the RESET button, the unit can start or
stop without using the remote control.
● Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
13
PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except airfl ow direction).
1. Select your preferred operation.
2. Press and hold
The P mark displays.
3. Press
: Operate the preset operation.
14
AUTO RESTART OPERATION
To automatically restart the air conditioner after the power failure (Power of
the unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds
to set the operation. ("Pi Pi Pi" sound and OPERATION lamp blink 5
times/sec for 5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. ("Pi Pi Pi" sound but OPERATION lamp does not
blink)
● In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
15
COMFORT SLEEP OPERATION
For comfortable sleep, automatically control air fl ow and automatically turn
OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
SELF CLEANING OPERATION
16
(COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
within 30 seconds.
17
MAINTENANCE
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
● Clean the indoor unit and the remote control with a wet cloth when
needed.
● No benzine, thinner, polishing powder or chemically-treated duster.
Air fi lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air fi lters.
3. Vacuum or wash and then dry them.
4. Reinstall the air fi lters and close the air inlet grille.
for 3 seconds to memorize the setting.
more 2 times
EN