MAINTENANCE
REPLACEMENT OF THE CERAMIC DISC HEAD VALVE
NOTE
For proper maintenance of the tap set we
recommend an inspection's door as shown
in the figure.
- Close the cold water and hot water inlets.
- Unscrew the locking dowel (1) using a 2
mm Allen wrench.
- Remove the handle (2),the hole cover plate
(3) and the plastic ring (4).
- Remove the plate (5), unscrew the locking
dowel (6) using a 2 mm Allen wrench and
remove the cap (7).
- Loosen the screw (8) and remove the ex-
tension (9).
- Unscrew the headvalve (10) with a 17 mm
tubular spanner socket wrench and replace it
with a new one (remove the reduction (11)
and assemble it on the new headvalve).
- Reassemble everything proceeding in the
opposite direction.
19