Preliminary Information; Technical Data - Cisal WAVE WA00025 Información Técnica

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21

PRELIMINARY INFORMATION

Mixers of the WAVE series are fit to
operate with hot water accumulators
under pressure, electrical and gas in-
stant water heaters.
WARNING: it is not possible to connect
them to hot water accumulators without
pressure (with open circuit).
- GB -

TECHNICAL DATA

- Minimum dynamic pressure ..................... 0,5 bar
- Maximum operational pressure /static) ......... 10 bar
- Recommended operational pressure (static).....1-5 bar
(N.B.: for pressure higher than 5 bar we suggest the
installation of a pressure reducer)
- Maximum test pressure (static) ................... 16 bar
- Maximum hot water temperature ................. 80 ° C
- Suggested hot water temperature ................. 60 ° C
(for energy saving).
Drill the top of the bathtub (or the
top) as shown in the figure. Hole A
(for the stem of the shower support)
is only for item WA00026 and can
be positioned on the left if necessary.
WARNING:
Do not remove the protective film
before installation.
- Insert the spout support (1) in the hole Ø52
– Ø56. Insert the gasket (2) between the sup-
port and the top.
- Install on the spout support (1) first the ga-
sket (3), then the steel washer (4) and finally
the hexagonal ring nut (5) tightening it with
Allen wrench 60.
- Assemble the cross connection (6) on the
stem of the spout support and lock it tighte-
ning the hexagonal nut (7) with Allen wrench
25.
- Insert the supply spout (8) and fasten it
to the spout support (1) with the screws (9)
tightening them with a 3 mm Allen wrench.
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wave wa00026

Tabla de contenido