3. Envelope is too thick. The intimus 1632 Letter Opener was designed to open typical
letter and business style envelopes (up to 4,5 mm thick).
4. Conveyor belts are worn beyond use. Call intimus Customer Service.
6.3 Envelopes feed more than one into the cutting blades
1. Holdback spring is weak or loose. Check to see if spring is in place. If so, it can be easi-
ly removed and bent to exert more pressure on the Holdback assembly .
6.4 Machine does not run at all
1. Check that the power cord is plugged into an active line.
2. Self-resetting breaker has tripped. The motor is protected by a built-in thermal breaker.
When the motor cools sufficiently, this self-resetting breaker will automatically reset and
the letter opener will start running again.
3. Electrical Malfunction. Call intimus Customer Service.
4. The motor drive belt has failed. Call intimus Customer Service.