4
TROUBLESHOOTING
Turntable does not operate
1. Make certain the turntable's AC cord is plugged into an AC outlet,
and that the AC outlet is "live"
2. A) Remove the slipmat from the turntable (Fig. 1)
Through an opening in the turntable platter, visually inspect to see if the
drive belt is around the motor pulley (Fig. 2)
B) if the drive belt is not around the motor pulley: Lift and remove the
turntable. Place a thumb into each of the left and right openings on the
turntable platter; and, using the fingers to press down on the turntable
housing's surface, pull the platter straight up (Fig. 3)
Avoid pressing on the tone arm
C) With the turntable platter bottom side up, place the belt along the
outside wall of the turntable platter's drive rim, making certain that the
belt is smooth and flat all the way around (Fig. 4)
D) Put the turntable back on the center spindle, make certain it is fully
seated, and align one of its openings over the motor pulley position
E) While holding both ends of the ribbon on the turntable belt, carefully
pull the belt over the motor pulley (Fig. 5) Make certain it does not
twisted
Turntable operates, but no sound at all
1. The stylus guard is still in place.
2. The tone arm Lift button is pressed in.
3. Amplifier controls set incorrectly.
4. Check the stylus on phono cartridge for correct placement.
Turntable operates, but no sound or sound not loud enough
1. If the turntable is connected to an AUX input. The Pre-amp
selector switch may be set to the "PHONO" position.
2. The input gain of the amplified speaker or similar device may be
too low.
3. The stylus assembly may not be fully seated in the cartridge body.
Sound is very distorted
Turntable connected to an amplifier's PHONO input. If the pre-amp
switch is set to the "LINE" position, a phono input will be overloaded
5
SPECIFICATIONS
Power supply
Power consumption
Dimensions
Load Impedance
Output Voltage
Weight
AC230V, 50Hz
10W
420 x 363.4 x 94mm
47K ohm
A. Connect with Equalizer
90-216mV at 1KHz 5cm/sec (HP-4005)
B. Connect without Equalizer
1.5-3.6mV at 1KHz 5cm/sec (HP-4005)
3.6kg
Drive belt
8
Motor pulley