Efapel sirius70 Manual Del Usuario página 41

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Ambient Sensor Monitoring - The temperature is monitored via the
equipment's ambient temperature sensor.
Note: When this monitoring mode is active, . will appear on the display. In this
operating mode, the Ambient Sensor will also perform Antifreeze/Overheating
Protection (see 2.6).
Floor Probe Monitoring - Temperature is monitored by the Floor
Probe.
Note: When this monitoring mode is active,
. will appear on the display. In
this operating mode, in addition to monitoring the temperature, the Probe will
also perform Antifreeze/Overheating Protection (see 2.6), preventing the floor
from exceeding the defined maximum/minimum temperatures set, thus avoiding
overheating/overcooling of the floor.
Ambient Sensor Monitor + Floor Probe - The temperature is
monitored via the equipment's ambient temperature sensor and
the Floor Probe, preventing overheating/overcooling of the floor
by preventing the floor temperature from exceeding the maximum/
minimum temperature limits set.
Note: When this monitoring mode is active,
will appear on the display. In
this mode, the temperature will be monitored by the Ambient Sensor and the
Probe will perform Antifreeze/Overheating Protection (see 2.6), preventing the
floor temperature from exceeding the defined maximum/minimum temperature
limits, thus avoiding overheating/overcooling of the floor.
41