Declaration Of Compliance - CEMO DT-Mobil CUBE 650 l Manual De Instrucciones

Ocultar thumbs Ver también para DT-Mobil CUBE 650 l:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
The vacuum leak indicator (item f) must be
checked at least once per week. If an alarm is
indicated (red range), the tank manufacturer or
an authorised specialist in accordance with § 19
of the Waste Management Act must be immedi-
ately notified. The function of the vacuum leak
indicator must also be tested by an expert once
a year by ventilating the monitoring space.
See also the technical description 138.0549.309
for the vacuum leak indicator.
Note: The original inspection is performed
in the factory prior to delivery.
A report about the recurring inspection
must be kept by the owner until the
next inspection at least.
Important
According to ADR 5.2.1.2 and 5.2.1.4, every fuel
tank must be clearly and permanently labelled on
both sides with the filling material and the hazard
label before being transported.
The UN number (UN 1202) for diesel fuel and
heating oil and the hazard label (flame against
a red background) are enclosed in duplicate.

Declaration of compliance

– Manufacturer
Hereby confirms that the
building product:
CEMO DT-Mobil CUBE with 652 or 1018 litres of
capacity
as IBC (IBC for transporting hazardous goods) with
the approval number
D/BAM 12668/31A
and the identification number
UN31A/Y/.. ../D/BAM 12668-CEMO5/2800/1041
or
UN31A/Y/.. ../D/BAM 12668-CEMO5/2800/1516
from the
factory:
CEMO5
conforms to the requirements of the technical
rules of the Building Rules List A No. 15.16 as well
as TRbF 20 (warehouses) and TRbF 60 (mobile
containers) based on the results of the production
check carried out in the factory by the manufacturer.
See also the Occupational Safety Directive,
specifically §§ 3, 6 and 9.
Purpose:
Collection, transport and delivery tank for extremely
flammable, highly flammable and flammable liquids
as well as for liquids with a flashpoint > 50 °C
and for non-combustible water-hazardous liquids
for which evidence of material compatibility in
accordance with the positive fluid list contained
in DIN 6601 is available.
The IBC is suitable for outdoor installation.
The certificate is valid in all states of the Federal
Republic of Germany.
Weinstadt, 1 July 2010
Managing Director
GB
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dt-mobil cube 980 l

Tabla de contenido