* T1 : Turn on time ( 500mS Max.)
* T2 : Rise time ( ≦ 20mS Max.)
* T3 : Power good turn on delay time ( 100 < T3 < 500 mS )
* T4 : Switch on time (10mS Max.)
* T5 : Power hold-on time ( 16 mS Min@60%load )
* T6 : Power good turn off delay time ( 1.0 mS Min.)
* Power on-off cycle :
When the power supply is turned off for a minimum of 2.0 sec. and turn on
again, the power good signal will be asserted.
10. MTBF
The MTBF of the power should be 100,000 hours min.
11. Burn-In
11.1 Input Voltage
Applying 220Vac .
11.2 Test Condition
Applying 100% loads for the power supply in 50 (+/-2) oC chamber
for 4 hours.
12. Harmonics
The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :1995
standard of class D, test at 230Vac 50Hz.
13.Power Factor
The power supply with active power factor correction, and meet the
EN61000-3-2 standards, The power factor is greater than 0.9 at 230V/50Hz,
Max. load.
14.Mechanical Specification
14.1Outline Dimension
150mmX86mmX180mm
15. Fanless Function
1. The fan does not turn when the load is less than 330W, but the fan will start to
cool down when the temperature inside the machine exceeds the safe range.
2. when the load exceeds 450W, the fan starts.
07