Notes: RAID Maintenance will not run under the following conditions.
・ If a previous error occurred during RAID Maintenance
・ During rebuilding
・ If RAID Maintenance is already running
RAID maintenance execution schedule
The available settings for the execution schedule of the RAID Maintenance are shown below.
・ Every week (The day of the week can be specified from Sunday, Monday, Tuesday, Wednesday,
Thursday, Friday, and Saturday.)
・ Week (1, 2, 3, 4) (The day of the week can be specified from Sunday, Monday, Tuesday,
Wednesday, Thursday, Friday, and Saturday.)
・ Weeks 1 and 3 (The day of the week can be specified from Sunday, Monday, Tuesday,
Wednesday, Thursday, Friday, and Saturday.)
・ Weeks 2 and 4 (The day of the week can be specified from Sunday, Monday, Tuesday,
Wednesday, Thursday, Friday, and Saturday.)
・ 1st of every month
The execution time can be specified in one-hour intervals from 00:00 to 23:00.
When [config] is clicked in the Option Setting screen, the next execution date and time is
calculated based on the current time. If the next execution is more than 30 minutes later, the
next execution only is set. If the next execution is within 30 minutes, and second execution is
also calculated and set.
Example: If the "Every week Sun." and "0:00" are set at 23:30 or earlier on Saturday, RAID
Maintenance is enabled 30 minutes later. If set at 23:31 or later, the function is set for
the next week.
Checking Details of the DriveStation and Hard Drive
Detailed information about the DriveStation (such as the number of hard drives, hard drive status,
fan status, and connection type) can be checked by clicking [File]-[Info] from the RAID Utility
menu.
Also, after [Advanced] is clicked in the Option Setting screen, clicking [File]-[Info] from the RAID
Utility menu shows the [Device Info] button. Clicking [Device Info] enables checking of the
detailed information for individual hard drives.
HD-QLU3 User Manual
29