1
VANITY INSTALLATION
Unpack Slate Vanity carefully, taking care that bottom of unit does not drop and damage metal feet.
Provide suitable reinforcement for anchoring the vanity to the wall. Centerline of reinforcement should be
31-1/4" up from the floor (see FIGURE 1.2).
Rough in supply lines and waste per rough-in dimensions (see FIGURE 1.1).
Decorative molding may need to be notched to seat the vanity flush against the wall.
Move the Slate Vanity into place and level with the adjustable levellers on the bottom of the feet. The
levellers can be adjusted outward up to 3/4" but it is recommended not to exceed 1/2" if possible.
Remove 1) Drawer and 2) Internal Upper Drawer from the drawer slides in order to access Top Rear Stringer
(see Figure 1.3)
Drill at least two 3/8" O.D. anchoring holes through the centerline of the Top Rear Stringer of the vanity.
Anchor the vanity securely to the wall through the Top Rear Stringer of the vanity (see FIGURE 1.3 / 1.4).
Continue with installation appropriate for sink and faucet options chosen.
IMPORTANT : Prior to cutting sink cut-out in wood top confirm that height of sink will clear Upper Drawer
(see FIGURE 1.4)
FIGURE 1.2
Units : Inches (mm)
C/L of 2 x 6
Reinforcement
31 1/4"
(793)
Finished
Floor
FIGURE 1.4
Units : Inches (mm)
22
(559)
20 1/2
(521)
1
(25)
6 3/4
(171)
UPPER
DRAWER
1 1/2
(38)
31 1/4
(793)
LOWER
DRAWER
3
(76)
SIDE VIEW
FIGURE 1.3
REMOVE
2)
INTERNAL
UPPER
DRAWER
REMOVE
1)
COMPLETE
DRAWER ASSEMBLY
4 3/4
(121)
SECURE VANITY
TO WALL USING
TOP REAR STRINGER
IMPORTANT:
BEFORE CUTTING THE SINK CUT-OUT
CONFIRM THAT SINK HEIGHT WILL
CLEAR THE UPPER DRAWER
ADJUSTABLE
LEVELLER UNDER
EACH FOOT
- 2 -
(CUT-AWAY VIEW)
ANCHOR VANITY
TO WALL
USING TOP
REAR STRINGER
7 3 0 1 2 9 2 - 1 0 0