Technical Specifications - STEINEL IR 180 UP Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Principle
With the IR 180 UP and HF 360 UP
sensor switches, groping for the light
switch is fi nally a thing of the past!
The intelligent sensor technology
switches the light ON automatically on
IR 180 UP:
8 m
max.
Angle of coverage: 180°
The IR 180 UP is equipped with
a pyro sensor which detects the
invisible heat emitted by moving
objects (pedestrians, animals etc.).
The heat thus detected is electroni-
cally converted and switches ON
connected consumers (e.g. a light).
No heat radiation is detected
through obstacles, such as walls
or glass and no switching therefore
occurs.
entering the room and OFF again after
the preset time. This is not only ex-
tremely convenient, but also increases
safety and is energy and cost saving.
HF 360 UP:
8 m
max.
Angle of coverage: 360°
The HF 360 UP is an active motion
detector. It reacts independently of
temperature to the slightest move-
ment. The integrated HF sensor
transmits high frequency electro-
magnetic waves (5.8 GHz) and re-
ceives their echo. In response to the
slightest movement in the detection
zone, the change in echo is per-
ceived by the sensor.
A microprocessor subsequently
triggers almost without delay the
switching command "light ON".
Detection is possible through doors,
panes of glass or thin walls.
- 14 -
Technical specifi cations
IR 180 UP
Dimensions:
(H x W x D) 80 x 80 x 55 mm
Output:
Filament bulbs, 1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max., at cos
inductive load at 230 V AC
4 x 58 W each max., C ≤ 88 μF
operating on 230 V AC
Connection:
230 V, 50 Hz
3-lead connection (L, L', N)
Contact gap:
between the contacts when unit is switched OFF
Installation height:
approx. 1.1 + 2.2 m
Sensor technology:
Infrared sensor
Transmission output:
Angle of coverage:
180° with 90° angle
of aperture
Reach:
8 m max.
Twilight setting:
2 - 2000 lux
Time setting:
5 sec. - 30 min.
Permanent light:
switchable (4 h)
Permanent light OFF: switchable
*
1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast
(total capacity of all connected ballasts below the value specifi ed).
*
2)
Installation above a door.
HF 360 UP
ϕ
= 0.5,
*1)
*2)
5.8 Ghz high frequency
approx. 1 mW
360° with 140° angle
of aperture
1 - 8 m
continuously adjustable
2 - 2000 lux
5 sec. - 30 min.
switchable (4 h)
switchable
- 15 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hf 360 up

Tabla de contenido