ADVANCED OPERATION 
The following Advanced Operation parameters require that you have an advanced controller like the model 45601 
LCD remote. Advanced remotes from other manufacturers may also be able to change these settings; however, 
basic remotes do not have this capability. 
All On/All Off 
Depending upon your primary controller, the 28166 plug‐in dimmer module can be set to respond to ALL ON and 
ALL OFF commands in up to four different ways. Some controllers may not be able to change the response from its 
default setting. Please refer to your controller's instructions for information on whether or not it supports the 
configuration function and if so, how to change this setting. 
The four possible responses are: 
‐ It will respond to ALL ON and the ALL OFF commands (default). 
‐ It will not respond to ALL ON or ALL OFF commands. 
‐ It will respond to the ALL OFF command but will not respond to the ALL ON command. 
‐ It will respond to the ALL ON command but will not respond to the ALL OFF command. 
Dim Rate Adjustments 
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to 
suit personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the 
default setting for parameter 8 is "3". This means that the lighting level will change every 30 milliseconds when the 
Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, 
the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum‐to‐
minimum or minimum‐to‐maximum brightness levels. 
1. When Receiving a Z‐Wave Dim Command 
‐ Parameter 7 (number of steps or levels) 
‐ Parameter 8 (timing of the steps) 
‐ Length: 1 Byte 
‐ Valid Values: 
Parameter 7 (default = 1) Valid Values: 1‐99 
Parameter 8 (default = 3) Valid Values: 1‐255 
2. Manual Control Dimming (pressing the Dimmer's button) 
‐ Parameter 9 (number of steps or levels) 
‐ Parameter 10 (timing of the steps) 
‐ Length: 1 Byte 
‐ Valid Values: 
Parameter 9 (default = 1) Valid Values: 1‐99 
Parameter 10 (default = 3) Valid Values: 1‐255 
3. When Receiving an All‐On or All‐Off Command 
‐ Parameter 11 (number of steps or levels) 
‐ Parameter 12 (timing of the steps) 
‐ Length: 1 Byte 
‐ Valid Values: 
Parameter 11 (default = 1) Valid Values: 1‐99 
Parameter 12 (default = 3) Valid Values: 1‐255 
 
 
 
 
 
 
 
 