Connect Electrical - Quick Connect Option
Wires should be covered to protect from foreign objects
AVISO
AVIS
NOTICE
!
!
!
!
ATTENTION
CAUTION
ATENCIÓN
DANGER
and water
ATTENTION
ATTENTION
ATTENTION
Ref.
Description
4A
RV Power Source
4A.1
Power Source Red Wire
4B
Ground Lug / Chassis Ground or negative battery terminal
Refer to Fig. 1 and Fig. 4.
Wire Size
■ Wire size is dependent on the distance between the pump
and power source. Actual wire sizes should be calculated
according to installation. Refer to Fig. 3.
■ Excess wire can be cut to length.
1. Disconnect red (positive) to the RV battery
2. Locate the power source (battery or other main power source)
where the electrical connection will be made.
(K5)
3. Cut the alligator clips
(K4)
4. Cut the fuse holder
use.
(K1)
5. Attach the pump
the wire leads on the pump to the desired length.
6. Cut the quick connect wiring (supplied) in half.
7. Crimp a quick connect plug onto the pump
Make sure the quick connect plug for the pump has the
NOTICE
socket end for the negative (black) wire.
www.thetford.com
4B
+
4A
4A.1
(4A)
.
off of the wire leads on the pump.
off of the red wire and save for later
(5A)
to the RV's drain outlet
(K1)
leads.
K3.2
K4
K3
Fig. 4
K3.1
Ref.
Description
K1
Pump Assembly
K1.4
Pump Red Wire
K1.5
Pump Black Wire
K3
Quick Connects
K3.1
Quick Connects Red Wire
K3.2
Quick Connects Black Wire
K4
Fuse Holder / 35AMP Fuse
8. Route a red wire (positive) from the power source to a loca-
tion near the RV's drain outlet.
9. Crimp the fuse holder
the power source.
10. Route a black wire (negative) from the battery's negative ter-
minal, or a ground lug on the RV, or an OEM provided chassis
ground to a location near the RV's drain outlet.
and cut
11. Crimp on a quick connect plug to the wire leads.
NOTICE
12. Protect all the wiring for the SaniCon system with a wire
sheath (not provided).
13. Reconnect the red (positive) cable that was removed in step 1
of this procedure to the RV's battery.
5
K1.4
K1
K1.5
(K4)
(Step 4) on to the red wire near
Make sure the quick connect plug going to the power
source has the socket end for the positive (red) wire.