D. Revitalizing
If after about 90 sec. between 7.5-10.5V are detected, a 12V battery is present. Charging starts with
a pulse charge for revitalizing. The voltage display 9 flashes. Once 10.5V are reached, the appliance
switches to the other charge steps.
Revitalizing is the same for all the 12V charge programmes.
E. Programme selection
NOTES: If a battery is detected in the voltage range of between 3.7-7.3V, the programmes 2-3-4
can not be selected.
The charging process takes place automatically.
Depending on the selected programme, the characteristic charge curve is monitored for voltage,
time and temperature. Included are the diagnostics programme, revitalizing mode and retention
charge.
«6V»
• Programme 1
For charging 6V batteries with a capacity of less than 14Ah.
• Press the programme selection button 10, to select programme 1. The symbol "6V" is displayed
on the LCD. During charging, the charge display 7 flashes and shows the progress of the charge
procedure (1-4 bars). When the battery is fully charged, the condition display 8 shows 4 bars. The
flashing stops and the appliance automatically switches to retention charge.
• Programme 2
For charging 12V batteries with a capacity of less than 14Ah.
• Press the programme selection button 10 to select programme 2. The symbol
on the LCD. During charging, the charge display 7 flashes and shows the progress of the charge
procedure (1-4 bars). When the battery is fully charged, the condition display 8 shows 4 bars. The
flashing stops and the appliance automatically switches to retention charge.
• Programme 3
For charging 12V batteries with a capacity between 14Ah-120Ah.
•
Press the programme selection button 10, to select programme 3. The symbol
on the LCD. During charging, the charge display 7 flashes and shows the progress of the charge
procedure (1-4 bars). When the battery is fully charged, the condition display 8 shows 4 bars. The
flashing stops and the appliance automatically switches to retention charge.
• Programme 4
For charging 12V batteries with a capacity between 14Ah-120Ah under cold conditions or for
charging AGM batteries.
• Press the programme selection button 10, to select programme 4. NOTE: This programme may
start with a minute delay. The symbol is displayed on the LCD. During charging, the charge display 7
flashes and shows the progress of the charge procedure (1-4 bars). When the battery is fully charged,
the condition display 8 shows 4 bars. The flashing stops and the appliance automatically switches
to retention charge.
4
(7.3V/0.8A) and 6.4V LiFePO4
"12V" (14.4V/0.8A) and 12.8V LiFePO4
"12V" (14.4V/3.8A) and 12.8V LiFePO4
"12V"(14.7V/3.8A) and 12.8V LiFePO4
is displayed
is displayed