D. CHARGING
The new battery is ready to be immediately installed but, if its voltage is not above 12.8 V, it is
recommended to charge it fully before use.
ATTENTION:
1. Use only for charging battery chargers specific for Lithium-Iron-Phosphate (LiFePO4) batteries.
2. Follow the parameters indicated below for the charge powers:
MODEL
GK-ATHBL-0003
GK-ATHBL-0004
Charge the battery with a current less than the maximum specified in the table.
3. To guarantee maximum operational battery life, do not charge at the maximum current for
more than 30 minutes, even if the battery is completely discharged.
4. The charge voltage must never exceed 15V.
5. If the battery heats up excessively, stop charging and wait until it has cooled down before
continuing with charging.
6. After charging, wait at least once hour before checking the voltage.
7. If the voltage is below 12.8V the battery must be charged further.
5/6 bars illuminated - livello di carica ottimale
Charging is not necessary
3/4 bars illuminated - sufficient charge level
Charging is recommended
1/2 bars illuminated - insufficient charge level (less than 12.8 V)
Charging is necessary
CHARGE VOLTAGE
STANDARD
MAXIMUM
14.4V
14.4V
STANDARD
LESS THAN 1
HOUR
14.6V
14.6V
7
CHARGE CURRENT
MAXIMUM
LESS THAN 30
MINUTES
2.5A
5A
2A
4A
EN