Blumfeldt Greenkeeper Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3. "Watering Days": Setting the pump on individual days. If the setting is
"01", the pump runs every day. If the setting is "06", the pump runs at an
interval of 6 days. The longest interval that can be set is 30 days.
4. "Watering Time": Length of the operating time of the pump. When the
setting shows "015", the pump runs for 15 seconds. The maximum setting
is 600 seconds.
Operating keys
1. SET key: Individual settings of the control (time, date, etc.). After pressing
6(7WKHUHVSHFWLYHIX Q FWLRQDVKHVLQWKHGLVSOD\ DQGLVUHDG\ WREH
programmed. Press SET again to move to the next setting and set the next
values.
2. Key +: go up one number
3. Key -: go down one number
4. OK button: Exit settings.
5. POWER key: Switch the control unit on or off. Press and hold the key for 5
seconds.
6. MAN key: Manual switching on and off of the pump. Press the key once
to start the pump. When MAN is pressed again, the pump stops working
again. By pressing the MAN button and simultaneously pressing the + and
- buttons, you can set the duration of pump operation.
7. Locking the control panel: Press and hold the + and - simultaneously. This
locks the keys. Press the + and - keys simultaneously to unlock the keys
again.
8. Press the SET key and the + and - keys to set the time.
EN
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

10031357

Tabla de contenido