Maddalena ElecTo BULK Instrucciones Para La Instalación, El Uso Y El Mantenimiento página 32

Ocultar thumbs Ver también para ElecTo BULK:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Install the meter in a position that is protected from freezing (insulate it if necessary with
insulation material) and in the lower part of the system to prevent air accumulation.
Install the meter in a position protected from blows and tampering, where readings are
easy to make.
Install the meter so that the direction of the arrow on the meter coincides with the flow
direction.
Install proper interception valves upstream and downstream from the meter to permit
maintenance operations and inspections on the meter, as well as to check the system.
WARNING!
l
Before positioning the seal, make sure that it is not damaged.
Make sure that the seal is not damaged during installation.
Make sure that the level of the seal is level with the tubing.
Check that the seal does not protrude from the tube.
Make sure that the surfaces of the flange are clean and undamaged.
32
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido