1.
Shut off the water at the main water supply. Remove the existing tub faucet
valve assembly.
Clean and dry the surface area where the new faucet will be mounted.
2.
Verify the hole sizes and positions in the tub deck are correct. For the cold
and hot water inlets, the holes should be 1-3/4 in. diameter. The center to
center distance between the cold water inlet on the right and the hot water
inlet on the left should be 8 - 16 in. NOTE: This kit allows up to 1-7/8 in.
deck thickness.
3.
Loosen the set screw (3.2) on the back of the faucet spout (A) with a 3 mm
Allen wrench (3.3) and disconnect the faucet spout (A) from connector (3.4) and
valve stem (3.5). Remove the connector (3.4) from the valve stem (3.5). Posi-
tion the rubber washer (3.6), metal washer (3.7), and mounting nut (3.8) at
the bottom of valve stem (3.5).
4.
From underneath the tub deck, insert the valve stem (4.1), with the rubber
washer (4.2), metal washer (4.3), and mounting nut (4.4) at the bottom, up
through the center hole in the tub deck (4.5). From above, thread the connector
(4.6) onto the valve stem (4.1). Tighten the mounting nut (4.4) using a basin
wrench, so the connector (4.6) sits flush against the tub deck surface.
5.
Install the faucet spout (A) onto the connector (5.1). Be sure the faucet spout (A)
is positioned firmly against the tub deck. Push down on the faucet spout (A)
and tighten the set screw (5.2) with a 3.2 mm Allen wrench (5.3). Insert the
index button (5.4) to cover the set screw on the faucet spout (A).
4
1
2
1-3/8 in.
Diameter
1-1/8 in.
Diameter
3
A
3.4
3.6
3.5
3.7
3.8
4
4.6
4.1
4.2
4.3
4.4
5
A
5.2
5.1
1-3/8 in.
Diameter
3.1
3.3
3.2
4.5
5.4
5.3

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

73-brt2-ar73-brt2-orb-ar115824512406951240697

Tabla de contenido